Delivery, placement and commissioning of PET CT
TenderZenith matches this tender's eligibility criteria against your company profile to calculate a deterministic qualification score and identify potential disqualifiers.
A structured breakdown of scope, eligibility requirements, submission steps, and key conditions — extracted directly from the official notice.
Sign in to unlock Bid Fit & AI Opportunity Intelligence
TenderZenith calculates a personalized qualification score against your company profile and extracts structured intelligence from tender documents with your 7-Day Pro Trial (No Credit Card Required).
Description & Project Overview
Explanation: Purchase, delivery and installation of a PET CT scanner, including table, all internal equipment work (server space, techniques, cooling) hardware and software and further finishing of the room. The current PET-CT is approaching its technical end of life and has insufficient capacity to adequately serve the current demand for PET-CT examinations. The demand for PET-CT examinations is expected to grow further. The resolution of the scanners is also no longer state-of-the-art. For the new system, we are looking for a high-end PET/CT scanner that will enable us to perform high-quality PET/CT research, both clinical and scientific. Since AZORG only has 1 PET CT and this will be unavailable to patients during the works, we would like to emphasize that limiting downtime throughout this entire project is very important. AZORG therefore expects rapid implementation, good coordination and smooth cooperation between the various contractors and our own construction team. Device plot + device related work: (PLEASE CHANGE SPECIFICATIONS! is a copy of the previous file from 2017) • High-end volume PET CT scan, minimum 16 acquisition slices. • System sensitivity ≥ 7.5 cps/kBq, measured according to the NEMA-2007 standard. • Possibility of Variable acquisition parameters within the same PET acquisition is included. • It is possible to synchronize acquisitions with the time of injection. • The possibility of reconstructing the images again (and possibly in a different way) after the date. • Ability to automatically archive reconstructed images on PACS. Image quality • System sensitivity ≥ 7.5 cps/kBq, measured according to the NEMA-2007 standard. • TOF – Time of Flight. • A flat radiotherapy bed is included • The presence of an external laser for radiotherapy. Maintenance • The warranty period is 2 years. • During the warranty period, the full comprehensive maintenance contract (maintenance) is valid