Get Free Access
TZ Ref No.: TZ-8D273B5
Tender Notice Urgent (6d left) 🌍 International (ICB) United States Healthcare and Medicine Infrastructure and construction Transportation

W099--Sources Sought Bulk Oxygen Rental & Support Services

Doc ref no. 36C2•••
Sector Healthcare and Medicine, Infrastructure and construction, Transportation
Publish Date 02 Nov 2026
Estimated Value Refer Document
Tender Intelligence
Qualification analysis + key highlights for this procurement

TenderZenith matches this tender's eligibility criteria against your company profile to calculate a deterministic qualification score and identify potential disqualifiers.

A structured breakdown of scope, eligibility requirements, submission steps, and key conditions — extracted directly from the official notice.

Sign in to unlock Bid Fit & AI Opportunity Intelligence

TenderZenith calculates a personalized qualification score against your company profile and extracts structured intelligence from tender documents with your 7-Day Pro Trial (No Credit Card Required).

Description & Project Overview

DESCRIPTION The Cincinnati Veterans Administration Medical Center (VAMC) has a requirement to provide Temporary Bulk Oxygen Rental & Support Services for Medical Gas Line Repair. The intention of this Sources Sought is to obtain information only. Please do not send a proposal. Requested information: To aid acquisition planning, we re seeking capable and interested firms for the information requested. If your firm meets the criteria please send the point of contract (ronald.heidemann@va.gov) the following, via email: Firm s Name Socio-Economic Status Whether or not your company has a contract vehicle we can order against If your company believes there is an alternative NAICS code please provide this If your company has any questions please provide. 1. Contract Title. Temporary Bulk Oxygen Rental & Support Services for Medical Gas Line Repair 2. Background. Provide a turnkey temporary bulk oxygen supply and services (rental tank, transport, installation, line hookup, controlled shutdown/bleeding, monitoring, and removal) to maintain uninterrupted oxygen service while VA performs a pin hole leak repair in the hospital s piped oxygen system. Work shall comply with VHA Directive 7515(1) and NFPA 99 Health Care Facilities Code requirements for medical gas systems 3. Scope: The Contractor shall furnish all rental equipment, labor, materials, transport, and qualified personnel to: Deliver and set a temporary bulk liquid oxygen (LOX) tank with vaporizers and regulators sized for hospital demand. Connect the temporary supply to the hospital oxygen pipeline (via EOSC/auxiliary connection or source valve), including gauges, check valves, and isolation devices; verify pressure, purity, and flow stability per NFPA 99 Chapter 5. Coordinate and execute a controlled shutdown and bleeding of affected lines, isolate zone valves, and validate alarm behavior with VA Clinical Engineering and Respiratory Therapy. Monitor supply, pressure, and alarms throughout the outage; maintain contingency oxygen cylinders for clinical areas at risk. Support VA repair team during line replacement/brazing and re-qualification (e.g., leak tests, purity checks, pressure verification), then transition back to the permanent bulk system and remove temporary equipment. 4. Specific Tasks : Temporary LOX tank with vaporizers sized to meet peak hourly demand; provide pressure regulating, relief, and check devices; all oxygen service compatible, oil free. Auxiliary/EOSC connection hardware, hoses, and valves compliant with facility EOSC design; include filtration as required. (NFPA 99 2024 emphasizes auxiliary connections for emergency preparedness.) Alarm interface: ensure master and area alarms receive accurate signals during temporary supply (low pressure, source changeover). Performance. Delivery requirements are met: Following VA repair and verification, transition back to primary bulk supply; execute valve re opening sequence, purge procedures, re pressurization, and alarm validation; document test results. Remove temporary equipment and restore site; submit as left drawings, pressure logs, and certification reports if applicable. 6. Place of Performance. Cincinnati VAMC, 3200 Vine Steet, Cincinnati, Ohio 45220 7. Delivery: Cincinnati VAMC 3200 Vine Street Cincinnati Ohio 45220

Days to Deadline
6 days
Closing: 11 Nov 2026, 18:00
Register to Bid Check Bid Capacity
· · Alert

Consortium & JV Partners

Matched
Need a Co-Bidder or Subcontractor?

Forming a Joint Venture increases technical eligibility and financial bonding capacity.

Post / Find JV Partners →

Key Procurement Details

Doc ref no. 36C2•••
Notice Type Tender Notice
Bidding Type ICB
Publish Date 02 Nov 2026
Sector Healthcare and Medicine, Infrastructure and construction, Transportation
Bid Security Sign in to view

Buyer Contact Information

Contact Details Locked

Procurement contact email, telephone, and buyer coordinates are unlocked upon starting your 7-Day Free Pro Trial.

Start 7-Day Free Trial →